Back to the product list

XGNC Series 75-800 SCFM

Non-Cycling Refrigerated Dryer

Our dryers are designed to deliver consistent, clean, dry air performance with a stable dew point. Featuring environmentally friendly R513A refrigerant with low Global Warming Potential (GWP), corrosion-resistant heat exchangers, and high-efficiency moisture separation, that ensure long-term reliability. Equipped with advanced microprocessor controls for easy system management and shipped with pre- and post-filtration for added protection. Each unit undergoes rigorous testing to guarantee leak-free operation, compliance with specifications, and certification to UL and CSA safety standards.

  • 75–800 SCFM
  • R513A refrigerant with low Global Warming Potential (GWP)
  • Corrosion-resistant heat exchangers
  • High-efficiency moisture separation
  • Advanced microprocessor control system
  • Variable-speed fans for optimized energy use and stable dew point
  • Pre and post-filtration with general-purpose and high-efficiency filters
  • Third-party certified: UL 60335-1, UL 60335-2-40, CSA 22.2 #60335-1, CSA 22.2 #60335-240
  • Integrated Timed Solenoid Drain

This dryer uses R513A refrigerant with low Global Warming Potential (GWP), supporting sustainability goals and compliance with environmental regulations. The use of R513A aligns with industry movement away from climate-damaging hydrofluorocarbons under the American Innovation and Manufacturing Act.  Its low pressure drop design improves energy efficiency, helping reduce operational costs. While high-quality components and extensive testing ensure reliable performance and minimize downtime. 

MODEL

Inlet Flow

Pressure Drop

VOLTAGE

IN/OUT

Power Consumption

Refrigerant

OVERALL DIMENSIONS (IN.)

OVERALL DIMENSIONS (MM)

SHIP Weight

Ship Weight

 

SCFM

NM³/H

PSI

 

AIR CONNECT SIZE

KW

 

W

D

H

W

D

H

LBS.

(KG)

XGNCA75

75

120

2.94

115/1/60

3/4" FPT

0.66

R513A

15.2

19.7

24.3

386.1

500.4

617.3

94

43

XGNCA100

100

160

3.5

115/1/60

3/4" FPT

0.85

R513A

15.2

19.7

24.3

386.1

500.4

617.3

99

45

XGNCA150

150

240

3.2

115/1/60

1 1/2"FPT

0.88

R513A

19.7

30.3

37.5

500.4

769.7

952.5

154

70

XGNCA200

200

321

4.4

115/1/60

1 1/2"FPT

1.12

R513A

19.7

30.3

37.5

500.4

769.7

952.5

170

78

XGNCA250

250

401

5.71

115/1/60

1 1/2"FPT

1.52

R513A

20.9

31.8

49.3

530.9

530.9

1252.3

440

200

XGNCA300

300

510

2.5

460/3/60

2"

2

R513 A

34.0

49.2

55.6

863.6

1249.7

1412.3

583

265

XGNCA400

400

680

3

460/3/60

2"

2.1

R513A

34.0

49.2

55.6

863.6

1249.7

1412.3

603

274

XGNCA500

500

850

1.5

460/3/60

3"

2.4

R513A

41.4

57.5

59.8

1051.6

1460.5

1518.9

1049

476

XGNCA600

600

1020

1.7

460/3/60

3"

2.7

R513A

41.4

57.5

59.8

1051.6

1460.5

1518.9

1074

488

XGNCA700

700

1190

2.2

460/3/60

3"

3.2

R513A

41.4

57.5

59.8

1051.6

1460.5

1518.9

1099

499

XGNCA800

800

1360

2.6

460/3/60

3"

4

R513A

41.4

57.5

59.8

1051.6

1460.5

1518.9

1124

510

Specified in accordance with ISO 7183

Table 2, A2 100 PSIG/100°F Inlet/100°F Ambient/100% Relative Humidity

See Price Book for additional Voltages