Back to the product list

Heated Blower Desiccant Air Dryers

It adopts the principle of blower heating to complete efficient drying of compressed air. It significantly saves the loss of compressed air and saves energy.

Use double-eccentric PTFE sealed butterfly valves to achieve reliable performance and long service life.

Use high-quality two-position five-way solenoid valves to control the pneumatic valves, thus ensuring the reliable operation of equipment.

Use reliable blowers to ensure the normal operation of the dryer system.

Use unique design to ensure the uniform distribution of dry and re generated air flow, thus eliminating the "short circuit" phenome- non of large central flow rate and small edge flow rate.

The tower body and hot pipe are insulated through external embossed aluminum sheets, thus eliminating energy waste. Specific pressurization function ensures uninterrupted air supply when the dryer is switched.

Use multiple measures to ensure that the bed is not loose, the desiccant is not worm, and the service time of desiccant is extended. The air flow through the dryer is slow, thus increasing the contact time with the desiccant, ensuring the dew point and reducing the pressure loss.

Each tower body is provided with a pressure gauge and a safety valve.

The regeneration circulation includes an appropriate cooling period to prevent dew point peaks from occurring during the switch. Standard configuration: PLC (programmable logic controller) and human-computer interface.

Heat regenerative

adsorption dryer (micro air consumption)

Model

Flow

Power

Air interface pipe diameter

Installed power

Dimensions (mm)

Weight

m3/min

V/Ph/hz

mm

kw

L w

H

kg

GD840IBRi

14

380/3/50

DN50

18.4

1500 800

2320

1320

GD1080IBRi

18

380/3/50

DN65

20.5

1500 800

2380

1360

GD1320IBRi

22

380/3/50

DN80

23.5

1700 1050

2400

1530

GD1500IBRi

25

380/3/50

DN80

23.5

1700 1050

2400

1570

GD1980IBRi

33

380/3/50

DN100

29.5

1900 1100

2520

2130

GD2640IBRi

44

380/3/50

DN100

43.5

2200 1150

2540

2890

GD3000IBRi

50

380/3/50

DN100

43.5

2200 1150

2540

2960

GD3600IBRi

60

380/3/50

DN125

54

2340 1250

2680

3750

GD4200IBRi

70

380/3/50

DN125

71

3300 1900

2780

5320

GD4800IBRi

80

380/3/50

DN125

71

3300 1900

2780

5360

GD5400IBRi

90

380/3/50

DN150

77

3360 2000

2860

7440

GD6000IBRi

100

380/3/50

DN150

77

3360 2000

2860

7480

GD7200IBRi

120

380/3/50

DN150

99

3600 2200

3030

8650

GD9000IBRi

150

380/3/50

DN200

123

3800 2300

3330

9800

GD12000IBRi

200

380/3/50

DN200

153.5

4200 2450

3400

11400

Heat regenerative adsorption dryer (zero air consumption)

Model

Flow

Power

Air interface

Installed power

Dimensions (mm)

Weight

m3/min

V/Ph/ hz

pipe diameter mm

kW

L

w

H

kg

GD840IBRi ZP

14

380/3/50

DN50

18.4

1800

1400

2400

1970

GD1080IBRi ZP

18

380/3/50

DN65

20.5

1800

1400

2400

2050

GD1320IBRi ZP

22

380/3/50

DN80

23.5

2200

1500

2500

2190

GD1500IBRi ZP

25

380/3/50

DN80

23.5

2200

1500

2500

2250

GD1980IBRi ZP

33

380/3/50

DN100

29.5

2200

1700

2550

2530

GD2640IBRi ZP

44

380/3/50

DN100

43.5

2400

1850

2600

3600

GD3000IBRi ZP

50

380/3/50

DN100

43.5

2400

1850

2600

3760

GD3600IBRi ZP

60

380/3/50

DN125

54

2720

1960

2750

4285

GD4200IBRi ZP

70

380/3/50

DN125

71

3500

2200

2800

5600

GD4800IBRi ZP

80

380/3/50

DN125

71

3500

2200

2800

5800

GD5400IBRi ZP

90

380/3/50

DN150

77

3480

2300

2900

6980

GD6000IBRi ZP

100

380/3/50

DN150

77

3480

2300

2900

7750

GD7200IBRi ZP

120

380/3/50

DN150

99

3600

2720

3050

8740

GD9000IBRi ZP

150

380/3/50

DN200

123

4000

2800

3350

10540

GD12000IBRi ZP

200

380/3/50

DN200

153.5

4250

3200

3460

13500

Note: reference working conditions for performance parameters: ambient temperature: 38��C; air inlet temperature: 38��C; working pressure:7 barg.