Mist Eliminators

Gardner Denver XGME Series Mist Eliminators are used to reduce energy costs and remove oil and water aerosols from compressed air systems. They also protect products and processes from contamination, increase the life of pneumatic equipment, help eliminate paint appearance and adhesion problems, and keep pneumatic instruments operating.  


Save money and operate responsibly 

  • Auditor's choice to reduce energy costs 
  • Protects products and processes from contamination 
  • Captures and retains large slugs of oil and water, should drain trap fail 
  • Protects downstream equipment from contamination should oil separator on rotary screw compressor fail 
  • Heavy duty ASME stamped pressure vessel 
  • Floor stand is standard 
  • Optional differential pressure gauge with reed switch available 

Save money and operate responsibly 

  • 125 – 10,000 SCFM 
  • Maximum Working Pressure: 150 PSIG 
  • Maximum Operating Temperature: 150°F 
  • Low pressure drop, saving energy 
  • Long life mist eliminator element - Standard 
  • Automatic Condensate Drain - Optional  


Model Number

Flow 100 psig (7 kgf/cm²)

Maximum Working Pressure

Maximum Operating Temp

Replacement Cartridge

Dimensions

Connections

Weight

Height

Width

scfm

M³/H

in

mm

in

mm

lbs

kg

FME1

125

200

150 psig

(14.1 kgf/cm²)

150° F

(66° C)

FME 1E

34.8

884

18.0

457

2" NPT

185

84

FME2

250

440

FME 2E

34.8

884

18.0

457

2" NPT

190

86

FME3

500

870

FME 3E

45.0

1143

18.0

457

2 ½" NPT

220

100

FME4

1100

1910

FME 4E

63.3

1608

23.8

605

4" ANSI FLG

350

159

FME5

1500

2600

FME 5E

70.8

1789

25.8

655

4" ANSI FLG

390

177

FME6

2100

3650

FME 6E

72.4

1839

31.8

808

4" ANSI FLG

700

318

FME7

2400

4170

FME 7E

72.4

1839

31.8

808

4" ANSI FLG

715

324

FME8

3000

5210

FME 8E

72.4

1839

31.8

808

4" ANSI FLG

730

331

Correction Factors for Inlet Pressure

Inlet Pressure

Multiplier

psig

kgf/cm²

 

20

1.4

0.30

30

2.1

0.39

40

2.8

0.48

60

4.2

0.65

80

5.6

0.82

100

7.0

1.00

120

8.4

1.17

150

10.5

1.43

  • Sizing: Maximum air flow at 100 psig (7 kgf/cm²) is indicated in the Specifications table.