FIXED SPEED MACHINES, 50 & 60 HZ
| MODEL | COOLING METHOD | DRIVE MOTOR | NOMINAL PRESSURE | FAD* | NOISE LEVEL** | WEIGHT | DIMENSIONS |
| 60 Hz | 50 Hz | 60 Hz | 50 Hz | L × W × H |
| HP | KW | PSIG | BARG | ACFM | M³/MIN | ACFM | M³/MIN | DB(A) | LBS | KG | LBS | KG | IN. (MM) |
T90 | Air | 125 | 90 | 100 125 150 | 6.9 8.6 10.3 | 631 597 530 | 17.9 16.9 15.0 | 614 582 517 | 17.4 16.5 14.6 | 78 | 7939 | 3601 | 8139 | 3692 | 107 × 72 × 87 (2712 × 1825 × 2200) |
| Water | 125 | 90 | 100 125 150 | 6.9 8.6 10.3 | 639 605 539 | 18.1 17.1 15.3 | 622 590 525 | 17.6 16.7 14.9 | 75 | 7648 | 3469 | 7848 | 3560 |
T110 | Air | 150 | 110 | 100 125 150 | 6.9 8.6 10.3 | 749 713 645 | 21.2 20.2 18.3 | 742 708 643 | 21.0 20.0 18.2 | 78 | 8051 | 3652 | 8662 | 3929 | 107 × 72 × 87 (2712 × 1825 × 2200) |
| Water | 150 | 110 | 100 125 150 | 6.9 8.6 10.3 | 756 721 653 | 21.4 20.4 18.5 | 750 716 651 | 21.2 20.3 18.4 | 75 | 7760 | 3520 | 8371 | 3797 |
T132 | Air | 175 | 132 | 100 125 150 | 6.9 8.6 10.3 | 856 819 750 | 24.2 23.2 21.2 | 872 837 768 | 24.7 23.7 21.7 | 78 | 8192 | 3716 | 9222 | 4183 | 107 × 72 × 87 (2712 × 1825 × 2200) |
| Water | 175 | 132 | 100 125 150 | 6.9 8.6 10.3 | 864 826 758 | 24.5 23.4 21.5 | 880 844 776 | 24.9 23.9 22.0 | 75 | 7901 | 3584 | 8931 | 4051 |
T160 | Air | 215 | 160 | 100 125 150 | 6.9 8.6 10.3 | 955 919 855 | 27.0 26.0 24.2 | 993 983 915 | 28.1 27.8 25.9 | 78 | 8402 | 3811 | 9226 | 4185 | 107 × 72 × 87 (2712 × 1825 × 2200) |
| Water | 215 | 160 | 100 125 150 | 6.9 8.6 10.3 | 962 926 863 | 27.2 26.2 24.4 | 1000 990 922 | 28.3 28.0 26.1 | 75 | 8111 | 3679 | 8935 | 4053 |
Data measured and stated in accordance with ISO1217 4th Edition Annex C and E at the following conditions:
Air Intake Pressure: 1 bar a/14.5 psi, Air Intake Temperature: 20°C/68°F, Humidity: 0% (dry)
Measured in free field conditions in accordance with the ISO 2151, tolerance ±3 dB(A)
VARIABLE SPEED MACHINES, 50* & 60 HZ
| MODEL | COOLING METHOD | DRIVE MOTOR | NOMINAL PRESSURE | FAD** | NOISE LEVEL*** | WEIGHT | DIMENSIONS |
| 50/60 Hz | 50/60 Hz | L × W × H |
| HP | KW | PSIG | BARG | ACFM | M³/MIN | DB(A) | LBS | KG | IN. (MM) |
TVS90 | Air | 125 | 90 | 100 125 150 | 6.9 8.6 10.3 | 626 564 517 | 17.7 16.0 14.6 | 64–78 | 7185 | 3259 | 107 × 72 × 87 (2712 × 1825 × 2200) |
| Water | 125 | 90 | 100 125 150 | 6.9 8.6 10.3 | 626 564 517 | 17.7 16.0 14.6 | 62–75 | 6894 | 3127 |
TVS110 | Air | 150 | 110 | 100 125 150 | 6.9 8.6 10.3 | 685 683 639 | 19.4 19.3 18.1 | 64–78 | 7185 | 3259 | 107 × 72 × 87 (2712 × 1825 × 2200) |
| Water | 150 | 110 | 100 125 150 | 6.9 8.6 10.3 | 685 684 639 | 19.4 19.4 18.1 | 62–75 | 6894 | 3127 |
TVS132 | Air | 175 | 132 | 100 125 150 | 6.9 8.6 10.3 | 879 814 772 | 24.9 23.0 21.9 | 64–78 | 8067 | 3659 | 107 × 72 × 87 (2712 × 1825 × 2200) |
| Water | 175 | 132 | 100 125 150 | 6.9 8.6 10.3 | 879 814 772 | 24.9 23.0 21.9 | 62–75 | 7776 | 3527 |
TVS160 | Air | 215 | 160 | 100 125 150 | 6.9 8.6 10.3 | 899 897 837 | 25.5 25.4 23.7 | 64–78 | 8067 | 3659 | 107 × 72 × 87 (2712 × 1825 × 2200) |
| Water | 215 | 160 | 100 125 150 | 6.9 8.6 10.3 | 900 897 836 | 25.5 25.4 23.7 | 62–75 | 7776 | 3527 |
50 Hz only applies to TVS90–TVS160 models.
Data measured and stated in accordance with ISO1217 4th Edition Annex C and E at the following conditions:
Air Intake Pressure: 1 bar a/14.5 psi, Air Intake Temperature: 20°C/68°F, Humidity: 0% (dry)
Measured in free field conditions in accordance with the ISO 2151, tolerance ±3 dB(A)