Capacity Correction Factors
| Inlet Pressure | 100° F | 105° F | 110° F | 115° F | 120° F | |
| psig | bar | 38° C | 40° C | 43° C | 46° C | 49° C |
| 60 | 4.2 | 0.65 | 0.64 | 0.62 | 0.6 | 0.58 |
| 70 | 4.9 | 0.74 | 0.73 | 0.71 | 0.69 | 0.66 |
| 80 | 5.6 | 0.83 | 0.81 | 0.8 | 0.77 | 0.74 |
| 90 | 6.3 | 0.91 | 0.89 | 0.87 | 0.85 | 0.81 |
| 100 | 7.0 | 1.00 | 0.98 | 0.96 | 0.93 | 0.89 |
| 110 | 7.7 | 1.04 | 1.02 | 1.00 | 0.97 | 0.93 |
| 120 | 8.4 | 1.08 | 1.06 | 1.04 | 1.00 | 0.96 |
| 130 | 9.1 | 1.12 | 1.10 | 1.08 | 1.04 | 1.00 |
| 140 | 9.8 | 1.16 | 1.14 | 1.11 | 1.08 | 1.03 |
| 150 | 10.5 | 1.20 | 1.18 | 1.15 | 1.12 | 1.07 |
To adjust DBS capacity for conditions other than rated, use the correction factors (multipliers) for inlet air temperature and pressure shown in the capacity correction factors table.
Example:Ques. What is the capacity of a 205 scfm (348 nm³/h) model when the compressed air at the inlet is 130 psig (9 bar) and 110° F (43° C)?
Ans. 205 scfm (348 nm³/h) (rated flow from product specifications table) x 1.08 (correction factor from inlet air temperature and pressure) = 221 scfm (375 nm³/h).